Transformer Oil Flow Indicator
Sudden Pressure Relay / Oil Surge Relay for Oil-Immersed Transformers
Model: DLF – 100 2 (TH)
1. Product Introduction
The oil flow indicator (also known as a sudden pressure relay or oil surge relay) is a passive, rapid-acting protective device installed in the connecting pipe between the transformer tank and the conservator (oil storage tank). It is widely used on oil-immersed power transformers, distribution transformers, and other oil-filled electrical equipment.
Under normal operation, the transformer oil flows slowly through the relay without actuating the contacts. When an internal fault (such as an arc or short circuit) causes a sudden pressure surge and rapid oil flow, the relay responds within milliseconds, operating its micro switch to trigger an alarm and trip signal, thereby protecting the transformer from further damage.
Working Principle
The indicator mainly consists of a housing, a flap (flow vane) mounted on a pivot, a return spring, a set of sealed electrical contacts, and an adjustable setpoint mechanism. The flap is positioned in the oil flow path inside the connecting pipe.
Under normal, steady oil flow the flap remains in its resting position under spring tension and the contacts stay open. When a fault generates a sudden pressure wave and high-velocity oil surge, the dynamic pressure acting on the flap overcomes the spring force, causing the flap to rotate rapidly. This movement directly drives the micro switch, closing (or opening) the sealed contacts to issue an instantaneous alarm / trip signal.
Because the device is entirely self-powered (passive), it requires no external supply and operates reliably even when the station auxiliary power is lost. After the fault is cleared, the flap automatically resets to its original position, ready for the next operation.
2. Model, Specification, Structure & Features
2.1 Model Designation
DLF – 100 2 (TH)
| Code | Meaning |
| DLF | Oil Flow Indicator (sudden pressure / oil surge relay) series |
| 100 | Nominal pipe / connection size (e.g. DN100); denotes the flange bore |
| 2 | Number of contacts / switches (2 groups: alarm + trip) |
| (TH) | Three-defense (salt fog / humidity / fungus) requirement, optional |
2.2 Construction & Working Principle
3. Technical Data
| Parameter | Specification |
| Product type | Oil Flow Indicator / Sudden Pressure Relay (oil surge relay) |
| Application | Oil-immersed power & distribution transformers |
| Installation position | Connecting pipe between tank and conservator |
| Rated pressure | As per transformer design (customizable) |
| Flow / pressure setpoint | Adjustable on site (typical 0.8–1.2 m/s oil velocity) |
| Response time | ≤ 10 ms (rapid acting) |
| Number of contacts | 2 groups (alarm + trip), SPDT |
| Contact capacity | AC 250 V / 5 A (resistive, typical) |
| Reset | Automatic (spring return) / manual reset optional |
| Connection (flange) | DN50 – DN150 (customizable) |
| Mounting orientation | As indicated on nameplate (arrow in oil-flow direction) |
| Enclosure protection | IP65 / IP66 (typical) |
| Body material | Cast aluminum alloy / stainless steel (optional) |
| Reference standard | IEC 60076-1, GB/T 6451 |
4. Key Features
5. Applications
6. Why Choose Us
7. Ordering Information
To select the correct oil flow indicator, please specify the following information when requesting a quotation:
| No. | Required Information | Example |
| 1 | Transformer rated power / voltage | 220 kV, 180 MVA |
| 2 | Connection pipe size (DN) | DN100 |
| 3 | Flow / pressure setpoint | 1.0 m/s (adjustable) |
| 4 | Number & type of contacts | 2 groups, SPDT (alarm + trip) |
| 5 | Mounting flange / special requirements | As per attached drawing |
Send us your transformer / conservator connection drawing (DWG / DXF / PDF) and we will provide a free technical proposal within 24 hours.